Products

FluCov2®
DyonFluCov2® is a rapid immunochromatographic test (ICT) kit that is used for simultaneous combined qualitative detection of antigens from Influenza A/B virus and SARS-CoV-2 in human nasopharyngeal and pharyngeal smear samples in order to tell them apart and be able to make differential diagnosis. This test is commonly used in the laboratory or in point-of-care analyses, as an aid in the diagnosis of influenza A virus and/or influenza B virus and coronavirus infection disease (COVID-19), which is caused by SARS-CoV-2 in a clinical specimen within a short period, relative to standard laboratory testing procedures. It is not intended to be used for self-testing, only by health professionals.

CORONA-Ag®

DyonCORONA-Ag® is a rapid immunochromatographic test (ICT) kit that is used for qualitative detection of SARS-CoV-2 antigen in human samples of pharyngeal smear (saliva), sputum and stool as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by SARS-CoV-2 in a clinical specimen within a short period, relative to standard laboratory testing procedures. This test is commonly used in the laboratory or in point-of-care analyses to aid the diagnosis of coronavirus disease (COVID-19) infection. It is not intended to be used for self-testing, only by health professionals.

DyonCOVID-Ag®
DyonDyonCOVID-Ag® is a rapid immunochromatographic test (ICT) kit that is used for qualitative detection of SARS-CoV-2 antigen in human nasopharyngeal and pharyngeal smear samples as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by SARS-CoV-2, in a clinical specimen within a short period, relative to standard laboratory testing procedures. This test is commonly used in the laboratory or in point-of-care analyses to aid the diagnosis of coronavirus disease (COVID-19) infection. It is not intended to be used for self-testing, only by health professionals.

DyonCovid19-S®
DyonDyonCovid19-S® is a rapid immunochromatographic test (ICT) kit that is used for qualitative detection of IgM and IgG antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in human serum, plasma or whole blood sample. It is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by SARS-CoV-2 . It is not intended to be used for self-testing, only by health professionals.

DyonCOVID19®
DyonCovid19® is a rapid immunochromatographic test (ICT) kit that is used for qualitative detection of IgM and IgG antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in human serum, plasma or whole blood sample. It is to be used as an aid in the diagnosis of coronavirus infection disease (COVID-19), which is caused by SARS-CoV-2 . It is not intended to be used for self-testing, only by health professionals.

DyonCRP® C-reactive protein
Using this product in 5 minutes and with 99% reliability you can:
  • Confirm the presence of an infection
  • Diagnose the severity of it by taking 3 different diagnostic values
  • Diagnose between viruses and bacterial infections

DyonMono® Infectious Mononucleosis
By applying this product to human capillary blood you can diagnose infectious mononucleosis caused by Epstein Barr virus (EBV)
Specificity and sensitivity greater than 99%

DyonStrepA-strip® Group A Streptococcus Antigen

By using a pharyngeal smear you can differentiate streptococcal infections from other biological markers with a sensitivity and specificity of 99%.

(http://www.cdc.gov/GETSMART/campaign-materials/info-sheets/adult-acute-pharyngitis.pdf) (http://www.cdc.gov/getsmart/campaign-materials/info-sheets/adult-acute-pharyngitis.html)

DyonFluA/B/H1N1® Influenza A/B/H1N1

Diagnosis and classification of influenza A, B but endemic H1N1 strain (reliability, compared with PCR = 82%).

DyonFlu A/H1N1® Influenza A/H1N1

Diagnosis and classification of influenza A and endemic H1N1 strain.

DyonFlu A/B® Influenza A/B

Diagnosis and overall classification of influenza in type A, B including all hypotypes.

Instructions for taking a nasopharyngeal smear

 

DyonHpsA® H. pylori stool Ag

The first in the world to test helicobacter pylori antigen with specificity, sensitivity, positive and negative prognostic value that reaches 99% in histological comparison studies.

  • Its reliability is not affected by the concomitant use of antecedent treatment
  • The success of helicobacter eradication may be assessed whether or not within 2 weeks after the end of antibiotic treatment, and the patient continues to receive antisecretory treatment.

DyonHpAb® Simple H. pylori Ab- IgG

Immediate and reliable testing of IgG antibodies against Helicobacter pylori in a drop of capillary whole blood.

  • As a Point of Care product it gives 93% reliability compared to histological biopsy.
  • The high level of reliability is due to the use of monoclonal antibodies.

DyonHpAb® Double H. pylori Ab IgG , IgM

Determination of IgG and IgM antibodies against Helicobacter pylori in a drop of capillary whole blood

  • As a Point of Care product it gives 93% reliability compared to histological biopsy.
  • The high level of reliability is due to the use of monoclonal antibodies
  • Specificity: 93% and Sensitivity: 97% compared to histologic
  • Positive and negative prognostic value compared to histological biopsy greater than 95%

DyonHpAb® Triple H. pylori Ab IgG , IgM, IgA

Determination of IgG, IgM and IgA antibodies against Helicobacter pylori in a drop of capillary whole blood

  • Determination of IgG, IgM and IgA antibodies against Helicobacter pylori in a drop of capillary whole blood
  • Specificity: 93% and Sensitivity: 97% compared to histologic
  • The high level of reliability is due to the use of monoclonal antibodies
  • Positive and negative prognostic value compared to histological biopsy greater than 95%

HelicotecUT® Test CLO Gel

Detects enzyme activity of Helicobacter pylori urease in gastric mucosal biopsy

  • Confirms 100% negative result in 24h
  • Specialty: 97% and Sensitivity: 99%

HelicotecUT® Plus Test Clo Paper

Detects enzyme activity of Helicobacter pylori urease in gastric mucosal biopsy

  • Confirms 100% negative result in 1h
  • Specialty: 97% and Sensitivity: 99%

Xeliac® Test Pro

Detection of IgA, IgG Transglutaminase Antibodies in a Droplet Capillary Whole Blood

  • Blockage or confirmation of celiac disease
  • Sensitivity and Specialty: 97%

DyonCombo® Calprotectin-Lactoferrin

Determination of specific inflammatory markers of calprotectin and lactoferrin in a faecal sample

 

DyonCalpro® Calprotectin

Determination of the specific rate of intestinal inflammation (calprotectin) in a faecal sample

  • The two different levels of detection are important in determining the severity of the inflammatory disease or in determining the phase of the disease (eg relapse).

DyonLacto® Lactoferrin

Determination of the specific rate of intestinal inflammation (lactoferrin) in a faecal sample. A highly specific assay in which lactoferrin responds with> 94% sensitivity and 93% specificity in 5 minutes.

 

DyoniFOB® Immunological Fecal Occult Blood

Microscopic examination of the presence of human hemoglobin in a faecal sample

  • Specialty and Sensitivity: 99%
  • Positive and negative predictive value greater than 97%
  • The high level of reliability is due to the use of monoclonal antibodies
  • There is no need for a special diet such as Mayer stools

DyoniFOB – Combo T® Immunological Fecal Occult – Blood & Transferrin

Microscopic examination of the presence of human hemoglobin and transferrin in a faecal sample

  • The high level of reliability is due to the use of monoclonal antibodies
  • There is no need for a special diet such as Mayer stools
  • The presence of transferrin gives a number of important diagnostic information about the possible digestive tract bleeding area

iFOB & Haptoglobin

Microscopic examination of human hemoglobin and haptoglobin in a faecal sample

  • The high level of reliability is due to the use of monoclonal antibodies
  • There is no need for a special diet such as Mayer stools

DyonCRP® C-reactive protein

By using this product in 5 minutes and with 99% reliability you can:

  • Confirm the presence of an infection
  • Diagnose its severity by taking 3 different diagnostic values
  • Diagnose between viral and bacterial infections

 

DyonAFP® α – fetoprotein, 10
  • Detection of fetoprotein A in a drop of whole capillary blood
  • Reliability and repeatability greater than 99%

 

 

 

DyonRota-Adeno® Rotavirus-Adenovirus
This product allows the medical professional to rapidly and accurately detect Rota virus – Adenovirus in stool samples of babies and children with gastroenteritis. Each virus is detected as a separate band.

DyonMono® Infectious Mononucleosis
By applying this product to human capillary blood you can diagnose infectious mononucleosis caused by Epstein Barr virus (EBV)
Specificity and sensitivity greater than 99%.

DyonStrepA-strip® Group A Streptococcus Antigen
By using a pharyngeal smear you can differentiate streptococcal infections from other biological markers with a sensitivity and specificity of 99%.

DyoniFOB® Immunological Fecal Occult Blood

Microscopic examination of the presence of human hemoglobin in a faecal sample

  • Specialty and Sensitivity: 99%
  • Positive and negative predictive value greater than 97%
  • The high level of reliability is due to the use of monoclonal antibodies
  • There is no need for a special diet such as Mayer stools

DyonTroponin® Troponin I/T

Troponin I determination in whole capillary blood sample (reliability – repeatability)> 99%

DyonMicroalbumin® Microalbumin

Determination of albumin level in urine sample(for ml of morning urination)

DyonDimer® D – Dimer

D-dimer determination in total capillary blood blockage 99% reliability, extremely high reliability and immediate diagnostic support in specific patient profiles

DyonTroponin POC® Cardiac Troponin

Determination of troponin I in whole capillary blood sample (reliability – repeatability)> 99% very high specificity at extremely low blood troponin concentrations

DyonCardiac 3 in 1® Cardiac Troponin, Myoglobin, CK-MB

Determining all three key heart markers separately, combining the answers can help significantly in the time of ischemic injury (reliability> 99%)

 

DyoniFOB® Immunological Fecal Occult Blood

Microscopic examination of the presence of human hemoglobin in a faecal sample

  • Specialty and Sensitivity: 99%
  • Positive and negative predictive value greater than 97%
  • The high level of reliability is due to the use of monoclonal antibodies
  • There is no need for a special diet such as Mayer stools

DyonBTA® Bladder Tissue Antigen

Antigen Detection for Early Diagnosis and Prevention of Bladder Cancer Based on International Guidelines.

DyonAFP® α-fetoprotein

Hepatocarcinoma Prevention in Hepatitis B or C Patients Detection of fetoprotein A in a drop of whole capillary blood Reliability and repeatability greater than 99%.

DyonPSA® Prostate Specific Antigen

Prevention of Prostate Cancer in Specific Patient Profiles but also in Specific Age Groups Based on International Guidelines.

Xeliac® Test Pro Anti- tTG IgA – IgG

Early diagnosis of celiac disease is an important contribution to the prevention and treatment of the disease and its effects.

DyonHpAb® Double H. pylori Ab IgG, IgM

Determination of symptomatic or asymptomatic patients in the presence or not of Helicobacter pylori, contribution to its timely treatment in specific population groups based on international guidelines.

Here you can define the content that will be placed within the current tab.